하중전이시험은 변형률계을 말뚝에 부착하여 심도별 변형률 측정하여 주면마찰력 분석

 

Rate of pile deflection η (millimeters per minute)

 

η = λ (PL/AE)

 

where λ = a soil constant

 

(0.1 for cohesionless soils, 0.04

for cohesive soils, or as specified by the DCES ) 1/minute,

 

P = pile design load, (kN) (as shown on the plans),

L = pile length, in. (mm)

A = pile area, (in2 (mm2)), and

E = pile modulus of elasticity, (GPa)).



x applied axial compression load, y vertical head deflection, elastic shortening

좌 주면 마찰력이 클 때, 우 주면마찰력이 작을 때

 



x applied axial compression load, y vertical head deflection, elastic shortening

좌 선단지지력이 클 때 , 우 선단지지력이 작을 때





x applied axial compression load, y vertical head deflection, elastic shortenin




x applied axial compression load ton, y average vertical head movement inches

head movement - load cell (적색 선)head movement - jack pressure (유압 적색 점선) 차이는 davisson offset criteria에서 70 ton 정도 차이가 발생하여 load cell을 사용해야 한다. 하중전이시험은 변형률계을 말뚝에 부착하여 심도별 변형률 측정하여 주면마찰력 분석 telltale





H 말뚝에 진동현식 변형률계 부착



콘크리트 말뚝에 진동식 변형률계 부착














콘크리트 강재가 결합된 복합말뚝에서 강재에 부착된 내부 변형률 ( blue) 와 외부 변형률계 (red) 차이





콘크리트 강재가 결합된 복합말뚝에서 강재에 부착된 내부 변형률 ( blue) 와 외부 변형률계 (red) 차이






콘크리트 강재가 결합된 복합말뚝에서 분리되어 내부 변형률(분홍)와 외부 변형률계(적색)차이





콘크리트 강재가 결합된 복합말뚝에서 분리되어 내부 변형률(분홍)와 외부 변형률계(적색)차이




tangent modulus





말뚝 심도별 tangent modulus, 작은 하중에서 변형률크기에 따라 다름






하중전이, 심도별 feet (y) 변형률계로 측정한 하중 ton (x)






심도별- unit shaft resistance 진동현식 (y) vs 하중 applied load (x) data

79 feet 말뚝에서 54 feet 까지 주면마찰력이 극한에 도달하고 54 feet 아래는 단단함





심도별 (y) - 단위주면마찰력(x) 변형률계 (적색) 과 말뚝 동재하 시험 CAPWAP해석 주면마찰력 (blue)




말뚝 연직 하중재하에서 측정요소




말뚝 연직 하중재하, 하중전이 시험 측정요소





말뚝 양방향재하에서 측정요소




static load test SLT에서 측정 할 수 있는 센서 형태





PDI SLT는 다양한 형태의 센서 측정할 수 있고 다수의 체널을 쉽게 연결

 

타사 제품은 다양한 형태의 센서를 연결할 수 없고 많은 선을 연결할 때 복잡함










현장 그래프