ceramic tip (tensiometer) 부간극수압 측정

Reading instantaneous profiles of soil water capillary pressure, moisture and salinity from arrays of the LP/p and LP/ms miniprobes

 

Features of LP/p probes:

Sensor:

o pressure diaphragm: a 15 mm long ceramic cup, 3 mm in diameter,

o pressure transducer: an integrated, fully active Wheatstone bridge with four piezoresistive strain gauge resistors diffused into a silicon diaphragm,

o air entry pressure: about 900 mbar (= 900cm=9m H2O),

 

offset drift: ± 20 mbar/month,

relative error: ± 15 %,

resolution: 1 mbar,

delay: 0 to 800 mbar in about 120 s, 800 to 0 mbar in about 3 s,

cable length: 2 m,

installation hole: 8 mm diameter,

tapped with 8x1 mm thread.

 

 

1mbar =1cm H2O = 0.001bar = 0.0102m H2O 1BAR =10.2 m H2O

66mbar = 66 x 0.0102 m H2O = 0.066m =60cm

 

 

설치 방법

 

부간극수압별 측정방법

 

 

 

실내시험 용 15 mm long ceramic cup, 3 mm in diameter

 

 

LP/p - laboratory probe for pressure of the soil capillary water

pressure diaphragm: a 15 mm long ceramic cup, 3 mm in diameter

air entry pressure: about 900 mbar

 

 